Post Offer Free
Tongdy Control Technology Co., Ltd  

Gold Index: 9977

You are here: home  > Modbus Interface Infrared CO2 Transmitter / NDIR CO2 Sensor HVAC

Modbus Interface Infrared CO2 Transmitter / NDIR CO2 Sensor HVAC 

Place of Origin: Guangdong, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: AIA-1

Specifications <table align="center" border="1" cellpadding="0" cellspacing="0" style="wi

Specifications
 

Monitoring parameters

CO2

Air Quality (VOC)

Temperature

Relative humidity

Sensing element

Non-Dispersive Infrared Detector (NDIR)

Semiconductor mix gases sensor

Digital combined temperature and humidity sensor

Measuring range

0~2000ppm(default)
0~5000ppm
(selectable in the order)

0~30ppm

0~50(32~122) (default)

0~100%RH

Display Resolution

1ppm

5ppm

0.1

0.1%RH

Accuracy@25(77)

±50ppm + 3% of reading

-------

±0.4 (0~50)

±3%RH (20%-80%RH)

Life time

15 years (normal)

57 years

10 years

Calibration cycle

ABC Logic Self
Calibration

        -------

---------

--------

Response Time

<2 minutes for 90% change

<1 minute
(for 10ppm hydrogen,
30ppm ethanol)
<5 minute
(for a cigarette)
in 20m2 room

<10 seconds to reach 63%

Warm up time

2 hours (first time)
2 minutes (operation)

 

Electrical Characteristics

Power supply

24VAC/VDC

 

Consumption

3.5 W max. ; 2.5 W avg.

 

Analog Outputs

Two or three analog outputs
0~10VDC(default) or 4~20mA (selectable by jumpers)
0~5VDC (selected at place the order)

 

Modbus RS485 interface

RS-485 with Modbus protocol, 19200bps rate, 15KV antistatic protection, independent base address

 

 

Conditions of Using and Installation

Operation conditions

0~50(32~122); 0~95%RH, non condensing

Storage conditions

0~50(32~122)/ 5~95%RH

Weight

320g

Installation

Fixed on the air duct with 100mm installation hole size

IP class of the housing

PC/ABS
IP50 for models without LCD; IP40 for models with LCD

Standard

CE-Approval

 
 
Features
  • Designed for real time detecting carbon dioxide, air quality, temperature or relative humidity in air ducts.
  • NDIR infrared CO2 sensor inside with special Self Calibration and up to 15 years’ lifetime. It makes CO2 measurement more accurate and reliable.
  • Mix gases sensor with high sensitivity for VOCs from new furnitures, wall coverings, office equipment, cleanser etc. and other pollutants from smoking and cocking etc.
  • Combined temperature and humidity digital sensor provides a high accuracy measurement in full range.
  • Provide up to 3 analog outputs (0~10VDC or 4~20mA or 0~5VDC) for CO2, air quality (VOC) and temperature or relative humidity.
  • Modbus RS485 interface with outputs for CO2, temperature, humidity and air quality (VOC).
  • With LCD or without LCD selectable
  • LCD display real-time measurements of CO2, air quality (VOC), temperature and relative humidity.
  • Simple and smart design and installation of sensor probe with a water-proof and porous film
  • Extendable probe meets more air duct systems
  • 24VAC/VDC power supply.
  • EU standard and CE-approval.

 
Application

  • Residential houses, exhibition halls, restaurants, shopping malls, sports gymnasiums, conference rooms, etc.

  • Museums, theaters, offices, classrooms, train stataions, airports, etc.

 
Dimensions and Mounting
 

 

 
 
 
Models Guide
 
TG9- X 1 8 2 LY 02/05 E Tab
 
X:  analog output
3- 3Xanalog outputs for CO2 + Air Quality (VOC) + Temp. /RH (selectable by jumpers)
2- 2xanalog outputs for CO2 + Air Quality (VOC)
0- no analog output
 
1Modbus interface (with outputs for real-time measurement of CO2+ Air Quality (VOC) +Temp. +RH)
 
8:  CO2 sensor code
 
2:  Air Quality (VOC) sensor code
 
L:  LCD display
No L indicates no LCD
Y:  Analog output type
A- 4~20mA   (selectable via jumpers)
V- 0~10VDC  (default)
V5- 0~5VDC  (NOTE: If 0~5VDC is chosen, then options of 0~10VDC or 4~20mA will not be available
 
02/05:  CO2 measurement range
02- 0~2000ppm  (default)
05- 0~5000ppm
 
E:  extended duct probe up to 209mm
No E indicates the standard probe length of 139mm
 
Tab:  temperature scaling
T05:      0~50(32~122) default 
T06:      0~60(32~140)
Without the item option indicates no output for temperature measurement.
 
 
Wiring Diagram
 

bigPhoto
 Mr. Tian Qing

Tel: 86-10-59738930
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Related Products

Company Info

Tongdy Control Technology Co., Ltd [China (Mainland)]


Business Type:Manufacturer
City: Beijing
Province/State: Beijing
Country/Region: China (Mainland)

You May Like:

Product (195)