Model No.: AIA-1

Specifications
 
<table border="1" cellpaddin

Specifications

 

Gas detected

Carbon Dioxide (CO2)

Sensing element

Non-Dispersive Infrared Detector (NDIR)

Accuracy@25(77),2000ppm

±40ppm + 3% reading

Stability

<2% of FS over life of sensor (15 yr typical)

Calibration interval

ABC Logic Self Calibration System

Response time

<2 minutes for 90% step change

Warm up time

2 hours (first time)

2 minutes (operation)

CO2 measuring range

02,000ppm (default)

05,000ppm available

CO2 Sensor life

More than 10 years

Power supply

24VAC/24VDC

Consumption

1.5 W max. ; 0.8 W avg.

Analog output

0~10VDC or 2~10VDC selectable by the jumper

Output select

PID control output or Linear output for CO2 measurement selectable via jumpers

Minimum opening

2V default and can be preset via RS485

Setpoints

Provide 4 CO2 setpoints for PID control:

CO2≥ 600ppm; CO2≥800ppm; CO2≥1000ppm(default); CO2≥1200ppm;

Selected by jumpers

 

Modbus interface

Modbus RS485 interface, 19200bps, 15KV antistatic protection.

6 LED lights

From left to right:

Green/Green/Yellow/Yellow/Red/Red

1st green light on as CO2 measurement≤600ppm

1st and 2nd green lights on as CO2 measurement>600ppm and≤800ppm

1st yellow light on as CO2 measurement>800ppm and≤1,200ppm

1st and 2nd yellow lights on as CO2 measurement>1,200ppm and≤1,400ppm

1st red light on as CO2 measurement>1,400ppm and≤1,600ppm

1st and 2nd red lights on as CO2 measurement>1,600ppm

Operation conditions

0~50(32~122); 0~95%RH, non condensing

Storage conditions

0~60(32~140)/0~80%RH

Net weight

180g

Dimensions

100mm×80mm×28mm

Installation standard

65mm×65mm or 2”×4”wire box

Approval

CE-Approval

 

Features

  • Real-time CO2 detection
  • NDIR infrared CO2 module with self-calibration and more than 10 years lifetime
  • Optional 6 LED lights indicating CO2 ranges
  • One 0~10VDC or 2~10VDC output
  • PID output for a VAV terminal with the setpoint of the minimum opening
  • Linear output available for CO2 measurements
  •  Optional Modbus RS485 interface
  • Four CO2 setpoints selectable via jumpers for PID output
  • The minimum opening can be set via RS485
  • Application for ventilation systems, BAS and single fan control etc.
  • Smart structure and easy mounting
  • CE-Approval

Model Guide

 

Type

Model

Description

   CO2 PID      Controller   

F2000TSM-CO2-S100-PID-02/05

1Xanalog output with PID (linear output selectable), CO2 range: 0~2,000ppm/0~5,000ppm

F2000TSM-CO2-S101-PID-02/05

1Xanalog output with PID (linear output selectable), Modbus interface.

CO2 range: 0~2,000ppm/0~5,000ppm

F2000TSM-CO2-L100-PID-02/05

6 LED lights indicates CO2 ranges.

1Xanalog output with PID (linear output selectable), CO2 range: 0~2,000ppm/0~5,000ppm

F2000TSM-CO2-L101-PID-02/05

6 LED lights indicates CO2 ranges.

1Xanalog output with PID (linear output selectable), Modbus interface.

CO2 range: 0~2,000ppm/0~5,000ppm

 

Wiring diagram

 

 

Mounting 

 

bigPhoto
 Mr. Tian Qing

Tel: 86-10-59738930
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Tongdy Control Technology Co., Ltd [China (Mainland)]


Business Type:Manufacturer
City: Beijing
Province/State: Beijing
Country/Region: China (Mainland)

You May Like:

Product (195)